eoReturn | SetType (uint8_t type) |
|
virtual eoReturn | SetCommand (uint8_t cmd) |
|
virtual eoReturn | Parse (const eoMessage &msg) |
| Parses a msg using learned in Profile from Device. More...
|
|
virtual eoReturn | SetValue (CHANNEL_TYPE type, uint32_t value, uint8_t index) |
|
| eoEEP_D21120 (uint16_t size=14) |
|
| eoD2EEProfile (uint16_t size=14) |
|
virtual eoReturn | CreateTeachIN (eoMessage &m) |
| Generates an EEP Telegram(only not chained supported!!1) More...
|
|
| eoEEProfile (uint16_t size=4) |
|
virtual eoReturn | GetValue (CHANNEL_TYPE type, float &value) |
| Gets the Value as Floating Point. More...
|
|
virtual eoReturn | GetValue (CHANNEL_TYPE type, uint8_t &value) |
| Sets the Value using a unsigned integer. More...
|
|
virtual eoReturn | GetValue (CHANNEL_TYPE type, uint32_t &value) |
|
virtual eoReturn | GetValue (CHANNEL_TYPE type, uint8_t &value, uint8_t subFlag) |
| Gets the Value as unsigned integer. More...
|
|
virtual eoReturn | GetValue (CHANNEL_TYPE type, uint32_t &value, uint8_t subFlag) |
|
virtual eoReturn | GetValue (CHANNEL_TYPE type, uint64_t &value, uint8_t subFlag) |
|
virtual eoReturn | GetValue (CHANNEL_TYPE type, float &value, uint8_t subFlag) |
| Gets the Value as Floating point. More...
|
|
virtual eoReturn | SetValue (CHANNEL_TYPE type, float value) |
| Sets the Value using a Floating Point. More...
|
|
virtual eoReturn | SetValue (CHANNEL_TYPE type, uint8_t value) |
| Sets the Value using a uint8_t. More...
|
|
virtual eoReturn | SetValue (CHANNEL_TYPE type, uint32_t value) |
|
virtual eoReturn | SetValue (CHANNEL_TYPE type, float value, uint8_t subFlag) |
| Gets the Value as a float. More...
|
|
virtual eoReturn | SetValue (CHANNEL_TYPE type, uint8_t value, uint8_t subFlag) |
| Gets the Value as unsigned integer. More...
|
|
virtual eoReturn | SetValue (CHANNEL_TYPE type, uint64_t value, uint8_t subFlag) |
| Sets the Value as a 64-bit. More...
|
|
virtual eoChannelInfo * | GetChannel (CHANNEL_TYPE type, uint8_t subType) |
|
virtual eoChannelInfo * | GetChannel (CHANNEL_TYPE type) |
|
virtual eoChannelInfo * | GetChannel (uint8_t channelNumber) |
|
virtual eoReturn | GetSubTypeChannel (CHANNEL_TYPE type, std::vector< eoEEPChannelInfo *> &vector) |
|
virtual uint8_t | GetChannelCount () const |
|
| eoProfile (uint16_t size=0) |
|
virtual bool | operator== (const eoProfile &othProfile) const |
|
virtual bool | operator!= (const eoProfile &othProfile) const |
|
virtual bool | IsSecDData (const eoMessage &message) |
|
virtual void | ClearValues () |
|
virtual eoReturn | Create (eoMessage &m) |
| Generates an EEP Message. More...
|
|
virtual uint8_t | Serialize (eoArchive &a) |
| Serialization Function which will be called by the eoStorageManager. More...
|
|
eoReturn | SetManufacturer (uint16_t manufacturerID) |
|
|
uint8_t | rorg |
| R-ORG.
|
|
uint8_t | func |
| Func.
|
|
uint8_t | type |
| Type.
|
|
uint16_t | manufacturer |
| Manufacturer.
|
|
static void | CopyItemToChannel (eoEEPChannelInfo &channel, EEP_ITEM const *item) |
|
static float | ScaleFromRAW (uint32_t rawValue, uint32_t rangeMin, uint32_t rangeMax, double scaleMin, double scaleMax) |
| Creates floating Point from Raw Value. More...
|
|
static uint32_t | ScaleToRAW (float value, uint32_t rangeMin, uint32_t rangeMax, double scaleMin, double scaleMax) |
| Creates Raw Value from a floating Point. More...
|
|
static eoReturn | GetRawValue (const eoMessage &msg, uint32_t &value, uint16_t offset, uint8_t size) |
| Gives raw data Value from a Message. More...
|
|
static eoReturn | SetRawValue (eoMessage &msg, uint32_t value, uint16_t offset, uint8_t size) |
| Inserts raw data Value in a message. More...
|
|
eoEEPChannelInfo * | channel |
| ChannelInfo list for direct Access to channels.
|
|
uint8_t | channelCount |
| Number of channels.
|
|
eoMessage | msg |
| helper function to convert bits
|
|
static const uint8_t | maskArray [8] |
| Mask array.
|
|
The class to handle eoEEP_D21120.
Allows the user to handle eoEEP_D21120 profile.
- For Message Direction: RCP -> Gateway/Actuatorgraphics/D2-11-20_ID3.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::TTP - Telegram Type |
1 | E_COMMAND | uint | ::MID - Message ID |
For Message Direction: RCP -> Gateway/Actuator graphics/D2-11-20_ID4.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::WMS - Work Mode Symbol |
1 | E_COMMAND | uint | ::MID - Message ID |
2 | E_STATE | uint | ::RCPM - Room Controller Panel Mode |
3 | E_STATE | uint | ::BS - Battery Status |
4 | E_STATE | uint | ::FC - Failure Code |
5 | E_STATE | uint | ::RTEMP - Room Temperature |
6 | S_TEMP | float | ::RTEMPCH0 - Room Temperature |
7 | E_STATE | uint | ::ACCTST - Air Condition Contact State |
8 | E_STATE | uint | ::FHO - Floor Heating Occupany / Power |
9 | E_STATE | uint | ::FHTSP - Floor Heating Temperature Setpoint |
10 | S_TEMP | float | ::FHTSPCH0 - Floor Heating Temperature Setpoint |
11 | E_STATE | uint | ::ACMSP - Air Condition Mode Setpoint |
12 | E_STATE | uint | ::ACFSP - Air Condition Fan Setpoint |
13 | E_STATE | uint | ::ACTS - Air Condition Temperature Setting |
14 | S_TEMP | float | ::ACTSCH0 - Air Condition Temperature Setting |
15 | E_STATE | uint | ::FVO - Floor Ventilation Occupany / Power |
16 | E_STATE | uint | ::FVSP - Fan Ventilation Setpoint |
For Message Direction: RCP -> Gateway/Actuator graphics/D2-11-20_ID5.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::WMS - Work Mode Symbol |
1 | E_COMMAND | uint | ::MID - Message ID |
2 | E_STATE | uint | ::RCPM - Room Controller Panel Mode |
3 | E_STATE | uint | ::BS - Battery Status |
4 | E_STATE | uint | ::FC - Failure Code |
5 | E_STATE | uint | ::RTEMP - Room Temperature |
6 | S_TEMP | float | ::RTEMPCH0 - Room Temperature |
7 | E_STATE | uint | ::ACCTST - Air Condition Contact State |
For Message Direction: RCP -> Gateway/Actuator graphics/D2-11-20_ID6.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::WMS - Work Mode Symbol |
1 | E_COMMAND | uint | ::MID - Message ID |
2 | E_STATE | uint | ::RCPM - Room Controller Panel Mode |
3 | E_STATE | uint | ::FVO - Fan Ventilation Occupany / Power |
4 | E_STATE | uint | ::FVSP - Fan Ventilation Setpoint |
5 | E_STATE | uint | ::FHO - Floor Heating Occupany / Power |
6 | E_STATE | uint | ::FHTSP - Floor Heating Temperature Setpoint |
7 | S_TEMP | float | ::FHTSPCH0 - Floor Heating Temperature Setpoint |
8 | E_STATE | uint | ::ACMSP - Air Condition Mode Setpoint |
9 | E_STATE | uint | ::ACFSP - Air Condition Fan Setpoint |
10 | E_STATE | uint | ::ACTS - Air Condition Temperature Setting |
11 | S_TEMP | float | ::ACTSCH0 - Air Condition Temperature Setting |
For Message Direction: RCP -> Gateway/Actuator graphics/D2-11-20_ID7.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_COMMAND | uint | ::MID - Message ID |
1 | E_STATE | uint | ::RCPM - Room Controller Panel Mode |
2 | E_STATE | uint | ::TSSO - Temperature Sensor Select Option |
3 | E_STATE | uint | ::ATC - Auto Transmit Period |
4 | E_STATE | uint | ::SSC - Sensor Sample Period |
5 | E_STATE | uint | ::ACT - Air Condition Type Option |
6 | E_STATE | uint | ::ACFO - Air Condition Fan Speed Option |
7 | E_STATE | uint | ::LOCK - Lock Mode |
8 | E_STATE | uint | ::FVS - Fan Ventilation Speed Option |
9 | E_STATE | uint | ::TSCV - Room Temperature Correct Value |
10 | S_TEMP | float | ::TSCVCH0 - Room Temperature Correct Value |
11 | E_STATE | uint | ::ACCTST - Air Condition Contact State |
12 | E_STATE | uint | ::FHTSR - Floor Heating Temperature Range Setting |
13 | E_STATE | uint | ::ACTSR - Air Condition Temperature Range Setting |
For Message Direction: Gateway/Actuator -> RCP graphics/D2-11-20_ID8.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::MCF - Message Continuation Flag |
1 | E_STATE | uint | ::RIN - Run Init Sequence |
2 | E_STATE | uint | ::MT - Message Type |
3 | E_COMMAND | uint | ::MID - Message ID |
For Message Direction: Gateway/Actuator -> RCP graphics/D2-11-20_ID9.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::MCF - Message Continuation Flag |
1 | E_STATE | uint | ::RIN - Run Init Sequence |
2 | E_STATE | uint | ::MT - Message Type |
3 | E_COMMAND | uint | ::MID - Message ID |
4 | E_STATE | uint | ::ES - Exception Status |
5 | E_STATE | uint | ::FHO - Floor Heating Occupany / Power |
6 | E_STATE | uint | ::FHTSP - Floor Heating Temperature Setpoint |
7 | S_TEMP | float | ::FHTSPCH0 - Floor Heating Temperature Setpoint |
8 | E_STATE | uint | ::ACMSP - Air Condition Mode Setpoint |
9 | E_STATE | uint | ::ACFSP - Air Condition Fan Setpoint |
10 | E_STATE | uint | ::FVSP - Fan Ventilation Setpoint |
11 | E_STATE | uint | ::ACTS - Air Condition Temperature Setting |
12 | S_TEMP | float | ::ACTSCH0 - Air Condition Temperature Setting |
13 | E_STATE | uint | ::FVO - Fan Ventilation Occupancy / Power |
14 | E_STATE | uint | ::WMS - Work Mode Symbol |
15 | E_STATE | uint | ::RTOV - Remote Temperature Original Value |
16 | S_TEMP | float | ::RTOVCH0 - Remote Temperature Original Value |
For Message Direction: Gateway/Actuator -> RCP graphics/D2-11-20_ID10.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::MCF - Message Continuation Flag |
1 | E_STATE | uint | ::RIN - Run Init Sequence |
2 | E_STATE | uint | ::MT - Message Type |
3 | E_COMMAND | uint | ::MID - Message ID |
4 | E_STATE | uint | ::ES - Exception Status |
5 | E_STATE | uint | ::RTOV - Remote Temperature Original Value |
6 | S_TEMP | float | ::RTOVCH0 - Remote Temperature Original Value |
For Message Direction: Gateway/Actuator -> RCP graphics/D2-11-20_ID11.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::MCF - Message Continuation Flag |
1 | E_STATE | uint | ::RIN - Run Init Sequence |
2 | E_STATE | uint | ::MT - Message Type |
3 | E_COMMAND | uint | ::MID - Message ID |
4 | E_STATE | uint | ::FVO - Fan Ventilation Occupany / Power |
5 | E_STATE | uint | ::FVSP - Fan Ventilation Setpoint |
6 | E_STATE | uint | ::WMS - Work Mode Symbol |
7 | E_STATE | uint | ::FHO - Floor Heating Occupany / Power |
8 | E_STATE | uint | ::FHTSP - Floor Heating Temperature Setpoint |
9 | S_TEMP | float | ::FHTSPCH0 - Floor Heating Temperature Setpoint |
10 | E_STATE | uint | ::ACMSP - Air Condition Mode Setpoint |
11 | E_STATE | uint | ::ACFSP - Air Condition Fan Setpoint |
12 | E_STATE | uint | ::ACTS - Air Condition Temperature Setting |
13 | S_TEMP | float | ::ACTSCH0 - Air Condition Temperature Setting |
For Message Direction: Gateway/Actuator -> RCP graphics/D2-11-20_ID12.png the following channels are available
Channel Index | Channel Type | Type | Comment |
0 | E_STATE | uint | ::MCF - Message Continuation Flag |
1 | E_STATE | uint | ::RIN - Run Init Sequence |
2 | E_STATE | uint | ::MT - Message Type |
3 | E_COMMAND | uint | ::MID - Message ID |
4 | E_STATE | uint | ::RCPM - Room Controller Panel Mode |
5 | E_STATE | uint | ::TSSO - Temperature Sensor Select Option |
6 | E_STATE | uint | ::ATC - Auto Transmit Period |
7 | E_STATE | uint | ::SSC - Sensor Sample Period |
8 | E_STATE | uint | ::ACFO - Air Condition Fan Speed Option |
9 | E_STATE | uint | ::LOCK - Lock Mode |
10 | E_STATE | uint | ::ACCTST - Air Condition Contact State |
11 | E_STATE | uint | ::ACT - Air Condition Type Option |
12 | E_STATE | uint | ::FVS - Fan Ventilation Speed Option |
13 | E_STATE | uint | ::TSCV - Room Temperature Correct Value |
14 | S_TEMP | float | ::TSCVCH0 - Room Temperature Correct Value |
15 | E_STATE | uint | ::FHTSR - Floor Heating Temperature Range Setting |
16 | E_STATE | uint | ::ACTSR - Air Condition Temperature Range Setting |